The DSC-1 is a 120V controlled outlet which is designed to turn on devices like ventilation fans if any fault or high CO2 level is detected. This module allows control of any CO2 device under the world voltage standard (100-240 VAC, 50/60 Hz), up to 10-amps.
LED status:
* Blinking green FAST: If the LED is blinking quickly, that means the module has not been addressed to the controller OR that module does not have a good connection to the controller. *Pressing the small button on the module will address/link the module when first installed.
* Blinking green SLOW: If you see a slowly blinking green LED, that means the module is addressed and connected to the controller, and the module is currently turned OFF.
* SOLID green: If you see the LED is on solid (no blinking) that means the modules are addressed, connected and currently turned ON.
* Blinking red: If you see the LED change to blinking red, that means the module has been overloaded. To reset the overload unplug the module from the power.
* By pressing and holding the button on the DSC-1, users can manually override the module and turn it ON / OFF.